MAX7313
Command Address Autoincrementing
The command address stored in the MAX7313 circu-
lates around grouped register functions after each data
byte is written or read (Table 2).
Device Reset
If a device reset input is needed, consider the
MAX7314. The MAX7314 includes a RST input, which
clears any transaction to or from the MAX7314 on the
serial interface and configures the internal registers to
the same state as a power-up reset.
Detailed Description
Initial Power-Up
On power-up all control registers are reset and the
MAX7313 enters standby mode (Table 3). Power-up
status makes all ports into inputs and disables both the
PWM oscillator and blink functionality.
Configuration Register
The configuration register is used to configure the PWM
intensity mode, interrupt, and blink behavior, operate
the INT/O16 output, and read back the interrupt status
(Table 4).
16-Port I/O Expander with LED Intensity
Control and Interrupt
12 ______________________________________________________________________________________
Figure 10. Read, Write, and Interrupt Timing Diagrams
SLAVE ADDRESS
123456789
SA6A5A4A3A2A1A00A0 000000
COMMAND BYTE
1A A AP
START CONDITION
ACKNOWLEDGE FROM SLAVE
ACKNOWLEDGE FROM SLAVE ACKNOWLEDGE FROM SLAVE STOP
CONDITION
P7–P0
P15– P8
DATA1 VALID
DATA2 VALID
SLAVE ADDRESS
123456789
S A6A5A4A3A2A1A0 1 A
COMMAND BYTE
ANA
START CONDITION
ACKNOWLEDGE FROM SLAVE
ACKNOWLEDGE FROM MASTER
P7–P0
P15–P8
STOP CONDITION
P
NO ACKNOWLEDGE FROM
MASTER
DATA2
DATA4DATA3
t
DV
t
DV
SLAVE ADDRESS
123456789
SA6A5A4A3A2A1A0 1 A
COMMAND BYTE
ANA
START CONDITION
ACKNOWLEDGE FROM SLAVE
ACKNOWLEDGE FROM MASTER
P7–P0
P15–P8
STOP CONDITION
P
NO ACKNOWLEDGE FROM
MASTER
DATA1 DATA2 DATA3 DATA4
DATA6DATA5
t
DH
t
DS
DATA1
t
IV
t
IR
t
IR
t
IV
SCL
SDA
SCL
SDA
SCL
SDA
WRITE TO OUTPUT PORTS REGISTERS (BLINK PHASE 0 REGISTERS/BLINK PHASE 1 REGISTERS)
READ FROM INPUT PORTS REGISTERS
INTERRUPT VALID/RESET
R/W
MSB LSBDATA1
MSB LSBDATA1
MSB LSBDATA2 MSB LSBDATA4
MSB LSBDATA6
MSB LSBDATA2
R/W
R/W
INT