Rainbow-electronics LM32 Uživatelský manuál Strana 20

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 24
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 19
2.0 Register Set (Continued)
Temperature Data Format (Continued)
Temperature Binary Hex
- 40 ˚C 11 1011 0000 3B0h
-255.5 ˚C 10 0000 0001 201h
-256 ˚C 10 0000 0000 200h
2.9.4 Temperature Control (Addr: 001 010; 0Ah)
This register is set to the reset value by a Device Reset.
Reg
Add
Register
Name
R/
W
P
O
R
Val
Bit
15
MSb
Bit
14
Bit
13
Bit
12
Bit
11
Bit
10
Bit
9
Bit
8
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
LSb
001 010
Temperature
Control
R/
W
0h
Reserved
EN2 EN1 EN0 ATE
000000000000
Bit Type Description
0 R/W ATE (Attention Enable). When set, this bit enables an Attention Request signal to be generated by the
LM32, if the EN0, EN1 or EN2 bits of this register are set.
0: Attention Request disabled (from enabled Temperature Sensor- default)
1: Attention Request enabled (from enabled Temperature Sensor)
1 R/W EN0 (Enable Sensor 0). When this bit is set, the Local Temperature Sensor is enabled for temperature
measurements.
0: Temperature Sensor disabled (default)
1: Temperature Sensor enabled
2 R/W EN1 (Enable Sensor 1). When this bit is set, the Remote Thermal Diode 1 Temperature Sensor is enabled
for temperature measurements.
0: Temperature Sensor disabled (default)
1: Temperature Sensor enabled
3 R/W EN2 (Enable Sensor 2). When this bit is set, the Remote Thermal Diode 2 Temperature Sensor is enabled
for temperature measurements.
0: Temperature Sensor disabled (default)
1: Temperature Sensor enabled
15-4 RO Reserved. Will always read "0".
2.10 CONVERSION RATE (Addr: 100 000; 20h)
Reg Add Register Name
R/
W
P
O
R
Val
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1
Bit 0
LSb
100 000 Conversion Rate
R/
W
2h
Reserved
CR1 CR0
000000
Bit Type Description
1-0 RO CR0 and CR1 (Conversion Rate bits 0 and 1) These bits control the conversion rate of the LM32 for
more details see Table Conversion Rate Control and desciption below.
7-2 RO Reserved. Will always read "0".
Conversion Rate Control
LowPwr [CR1:CR0] Typical Conversion Rate (ms)
0 00 Fastest*: continuous
100 91
LM32
www.national.com 20
Zobrazit stránku 19