MAX6668/MAX6670
Remote Temperature Switches with Integrated
Fan Controller/Driver
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
DD
= +3V to +3.6V, T
A
= -40°C to +125°C, unless otherwise noted. Typical values are at V
DD
= +3.3V and T
A
= +25°C.)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
V
DD
to GND..............................................................-0.3V to +6V
PGND to GND .......................................................-0.3V to +0.3V
FANOUT to GND ....................................................-0.3V to +15V
DXN to GND ..........................................................-0.3V to +0.8V
DXP, WARN, HYST, FORCEON, OT...........-0.3V to (V
DD
+ 0.3V)
Current into V
DD
, GND, DXP, DXN, WARN, HYST,
FORCEON, OT..............................................................±20mA
Current into FANOUT, PGND ........................................ ±300mA
Continuous Power Dissipation (T
A
= +70°C)
8-Pin µMAX (derate 4.1mW/°C above +70°C).............333mW
10-Pin µMAX (derate 5.6mW/°C above +70°C) ...........444mW
Operating Temperature Range .........................-40°C to +125°C
Storage Temperature Range .............................-60°C to +150°C
Junction Temperature......................................................+150°C
Lead Temperature (soldering, 10s) .................................+300°C