and 100µA, the change in the measured voltage due to
series resistance is:
Since 1°C corresponds to 198.6µV, series resistance
contributes a temperature offset of:
Assume that the sensing diode being measured has a
series resistance of 3. The series resistance con-
tributes a temperature offset of:
The effects of the ideality factor and series resistance
are additive. If the diode has an ideality factor of 1.002
and series resistance of 3, the total offset can be cal-
culated by adding error due to series resistance with
error due to ideality factor:
1.36°C - 2.13°C = -0.77°C
for a diode temperature of +85°C.
3 0 453 1 36
×
°
=+ °. .
C
C
90
198 6
0 453
µ
µ
V
V
C
C
.
.
°
=
°
VAARAR
MSS
=−×=×()100 10 90µµ µ
MAX6695/MAX6696
Dual Remote/Local Temperature Sensors with
SMBus Serial Interface
_______________________________________________________________________________________ 7
OT2
OT1
ALERT
DXP2
DXN
DXP1
RESET/
UVLO
CIRCUITRY
V
CC
(RESET)
MUX
REMOTE1
REMOTE2
LOCAL
Q
S
R
OT2 THRESHOLDS
ALERT RESPONSE ADDRESS
ALERT THRESHOLD
LOCAL TEMPERATURES
REMOTE TEMPERATURES
COMMAND BYTE
REGISTER BANK
Q
S
R
Q
S
R
ADC
CONTROL
LOGIC
8
8
SMBus
READ
WRITE
(STBY)
SMBDATA
SMBCLK
(ADD0)
(ADD1)
ADDRESS
DECODER
3
DIODE FAULT
() ARE FOR MAX6696 ONLY.
7
OT1 THRESHOLDS
Figure 1. MAX6695/MAX6696 Functional Diagram