GE863 Hardware User Guide
1vv0300783 Rev.0 - 10/06/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 16 of 80
NOTE: don't use any pull up resistor on the RESET* line nor any totem pole digital output. Using pull up resistor
may bring to latch up problems on the GE863-GPS power regulator and improper functioning of the module. The
line RESET* must be connected only in open collector configuration.
TIP: The unconditional hardware shutdown should be always implemented on the boards and software should use
it as an emergency exit procedure.
For example:
1- Let's assume you need to drive the RESET# pad with a totem pole output of a +3/5 V
microcontroller (uP_OUT2):
10k