ATmega128(L)
2467B09/01
Voltage Reference Enable
Signals and Start-up Time
The voltage reference has a start-up time that may influence the way it should be used.
The start-up time is given in
Table 20. To save power, the reference is not always turned
on. The reference is on during the following situations:
1. When the BOD is enabled (by programming the BODEN fuse).
2. When the bandgap reference is connected to the Analog Comparator (by setting
the ACBG bit in ACSR).
3. When the ADC is enabled.
Thus, when the BOD is not enabled, after setting the ACBG bit or enabling the ADC, the
user must always allow the reference to start up before the output from the Analog Com-
parator or ADC is used. To reduce power consumption in power down mode, the user
can avoid the three conditions above to ensure that the reference is turned off before
entering power down mode.
Note: 1. Values are guidelines only. Actual values are TBD.
Watchdog Timer The Watchdog Timer is clocked from a separate on-chip oscillator which runs at 1 Mhz.
This is the typical value at V
CC
= 5V. See characterization data for typical values at other
V
CC
levels. By controlling the Watchdog Timer prescaler, the Watchdog reset interval
can be adjusted as shown in
Table 22 on page 52. The WDR Watchdog Reset
instruction resets the Watchdog Timer. The Watchdog Timer is also reset when it is dis-
abled and when a chip reset occurs. Eight different clock cycle periods can be selected
to determine the reset period. If the reset period expires without another Watchdog
reset, the ATmega128 resets and executes from the Reset vector. For timing details on
the Watchdog reset, refer to
page 48.
To prevent unintentional disabling of the watchdog or unintentional change of time-out
period, 3 different safety levels are selected by the Fuses M103C and WDTON as
shown in Table 21. Safety level 0 corresponds to the setting in ATmega103. There is no
restriction on enabling the WDT in any of the safety levels. Refer to
“Timed Sequences
for Changing the Configuration of the Watch Dog Timer” on page 53
for details.
Table 20. Internal Voltage Reference Characteristics
(1)
Symbol Parameter Condition Min Typ Max Units
V
BG
Bandgap reference voltage TBD TBD 1.23 TBD V
t
BG
Bandgap reference start-up time TBD 40 70 µs
I
BG
Bandgap reference current
consumption
TBD 10 TBD µA